Axial length of the eye
Measured in millimeters; its lengthening is an important indicator of myopia progression.
We show scientific research in which the authors used the EyeRising device, also known as Eyerising Myopia Management Device (EMMD). This makes it easier to distinguish studies of this therapy from the broader literature about RLRL.
View publicationsAL and SER help describe change in the study group. They do not predict the outcome for a specific child.
Measured in millimeters; its lengthening is an important indicator of myopia progression.
A standardized recording of refractive error in diopters, used to compare changes between visits.
New · September 10, 2026
Three-year comparison with orthokeratology during active treatment. Read the result and its limitations together.
The study followed 86 children with myopia for 3 years. 40 children used RLRL therapy with the EyeRising device, and 46 children were treated with orthokeratology.
After three years, the average axial eye length in the EyeRising group practically did not increase - the average change was 0.00 mm. In the orthokeratology group, the average axial elongation was +0.45 mm.
In practice, this means that in the studied group of children using EyeRising, a very strong inhibition of eye lengthening, one of the most important parameters of myopia progression, was observed.
The authors reported the so-called complete myopia control in 82.5% of children in the RLRL group, compared with 37.0% of children in the orthokeratology group.
There were no treatment-related serious adverse events reported in the study.
Device identification: The intervention section explicitly lists EyeRising device (Suzhou Xuanjia Optoelectronics Technology Co., Ltd.).
Limitations: The study was retrospective, single-center and non-randomized. The results describe clinical follow-up during active treatment and do not constitute proof of causal superiority of one therapy over another.
Declaration of interests of the authors
Mingguang He declared as a director and shareholder of Eyerising Ltd and Eyerising International Pty Ltd.
Clinical basis
A focused set of evidence for the device: randomised trials, sham control, post-trial follow-up and a high-myopia group.
Primary multicenter randomized trial: 264 children assigned to groups; AL and SER were assessed for 12 months.
Device identification: Full publication identifies Eyerising (Suzhou Xuanjia Optoelectronics Technology).
Limitations: Results refer to study population, protocol and follow-up time; they are not predictive of effectiveness in an individual child.
Randomized, double-blind comparison with a reduced-power sham device.
Device identification: The intervention description names Eyerising (Suzhou Xuanjia Optoelectronics Technology).
Limitations: The result is related to the sham control used and the observation period; does not determine the durability of the effect after the end of therapy.
Follow-up of participants in a prior RCT: describes continuation of therapy, second year of follow-up, and post-treatment change, including rebound.
Device identification: The methods indicate desktop light therapy device (Eyerising, Suzhou Xuanjia Optoelectronics Technology).
Limitations: The second year was not a new, independent randomized trial.
Multicenter, randomized study of 192 children and adolescents with high myopia; observation lasted 12 months.
Device identification: The full publication in the description of the intervention includes a portable desktop device (Eyerising International).
Limitations: The authors indicate the need for further evaluation of long-term efficacy and safety.
Device safety
Exposure analysis and an individual clinical safety signal require separate interpretation. Assessment of suitability for therapy, symptom monitoring and OCT remain important.
Radiometric analysis and modeling of device-specific exposure safety.
Device identification: The authors analyze directly Eyerising Myopia Management Device (EMMD).
Limitations: This is a preprint that has not undergone scientific peer review, not a clinical trial in children. It does not, on its own, establish safety in clinical practice.
Retinal damage was described in one child after exposure. This safety signal requires attention during the assessment of suitability for therapy and subsequent monitoring.
Device identification: Case report mentions Eyerising (Suzhou Xuanjia Optoelectronics Technology).
Limitations: The single case report does not indicate the incidence of the event or the population risk; is not a cohort study.
Further reading
This page only shows publications directly related to EyeRising / EMMD. The complete RLRL literature - studies of other devices, meta-analyses, method comparisons, safety, long-term follow-up and mechanism - is maintained on separate evidence sites.